MATEOU / AIR TREATMENT

SJKW SeriesMicro-Heat Desiccant Air Dryers

Micro-Heat Regenerative Desiccant Air Dryers

Micro-heat regenerative desiccant dryers use twin adsorption towers to remove moisture from compressed air. Select the rated air flow capacity, operating pressure and required pressure dew point for your process. Heatless alternatives are available on request.

  • Drying method: Twin-tower desiccant adsorption
  • Regeneration: Micro-heat
  • Working pressure: 6–10 bar catalogue range
Rated air flow capacity1.5–27 m³/min
Listed models9

SJKW MODEL SPECIFICATIONS

Compare dryer capacity.
Find your dryer.

Select a model to expand its specifications here. Compare rated air flow capacity, operating conditions and connection sizes.

9 modelsSelect View specs for full details ↓
Dryer models with specifications that expand in this table.
ModelRated air flow capacitym³/min / CFMWorking pressurebarAir connectionDimensionsL × W × H / mm
1.5 m³/min53 CFM6–10 barG 3/4800 × 350 × 1080
SJKW-1 / Full specifications

SELECTED MODEL

SJKW-1

1.5 m³/min / Micro-heat regenerative desiccant dryer

Equipment specifications
ModelSJKW-1
Drying configurationMicro-heat
Rated air flow capacity1.5 m³/min / 53 CFM
Working pressure6–10 bar
Maximum inlet temperature45 °C
Air connectionG 3/4
Dimensions / L × W × H800 × 350 × 1080 mm
Reference weight105 kg
Catalogue voltage220 V
Catalogue power limit1.5 kW
Application & installation
Drying methodTwin-tower desiccant adsorption with micro-heat regeneration
Selection inputsAir flow / inlet temperature / working pressure / required air quality
Electrical configurationFrequency, phase and final voltage confirmed with quotation
Air treatmentPre-filtration and downstream dust filtration matched to the application
Other configurationsHeatless models available on request

Rated air flow capacity is the compressed-air flow the dryer can treat, not air produced by the dryer. Match the rating basis, inlet and ambient temperatures, working pressure and required pressure dew point to your system. For desiccant dryers, allow for regeneration air when assessing the net flow available to production.

2.5 m³/min88.3 CFM6–10 barG 3/4800 × 350 × 1310
SJKW-2 / Full specifications

SELECTED MODEL

SJKW-2

2.5 m³/min / Micro-heat regenerative desiccant dryer

Equipment specifications
ModelSJKW-2
Drying configurationMicro-heat
Rated air flow capacity2.5 m³/min / 88.3 CFM
Working pressure6–10 bar
Maximum inlet temperature45 °C
Air connectionG 3/4
Dimensions / L × W × H800 × 350 × 1310 mm
Reference weight125 kg
Catalogue voltage220 V
Catalogue power limit1.5 kW
Application & installation
Drying methodTwin-tower desiccant adsorption with micro-heat regeneration
Selection inputsAir flow / inlet temperature / working pressure / required air quality
Electrical configurationFrequency, phase and final voltage confirmed with quotation
Air treatmentPre-filtration and downstream dust filtration matched to the application
Other configurationsHeatless models available on request

Rated air flow capacity is the compressed-air flow the dryer can treat, not air produced by the dryer. Match the rating basis, inlet and ambient temperatures, working pressure and required pressure dew point to your system. For desiccant dryers, allow for regeneration air when assessing the net flow available to production.

3.8 m³/min134.2 CFM6–10 barG 1820 × 380 × 1610
SJKW-3 / Full specifications

SELECTED MODEL

SJKW-3

3.8 m³/min / Micro-heat regenerative desiccant dryer

Equipment specifications
ModelSJKW-3
Drying configurationMicro-heat
Rated air flow capacity3.8 m³/min / 134.2 CFM
Working pressure6–10 bar
Maximum inlet temperature45 °C
Air connectionG 1
Dimensions / L × W × H820 × 380 × 1610 mm
Reference weight170 kg
Catalogue voltage220 V
Catalogue power limit2.5 kW
Application & installation
Drying methodTwin-tower desiccant adsorption with micro-heat regeneration
Selection inputsAir flow / inlet temperature / working pressure / required air quality
Electrical configurationFrequency, phase and final voltage confirmed with quotation
Air treatmentPre-filtration and downstream dust filtration matched to the application
Other configurationsHeatless models available on request

Rated air flow capacity is the compressed-air flow the dryer can treat, not air produced by the dryer. Match the rating basis, inlet and ambient temperatures, working pressure and required pressure dew point to your system. For desiccant dryers, allow for regeneration air when assessing the net flow available to production.

6.8 m³/min240.1 CFM6–10 barG 1 1/2940 × 530 × 1850
SJKW-6 / Full specifications

SELECTED MODEL

SJKW-6

6.8 m³/min / Micro-heat regenerative desiccant dryer

Equipment specifications
ModelSJKW-6
Drying configurationMicro-heat
Rated air flow capacity6.8 m³/min / 240.1 CFM
Working pressure6–10 bar
Maximum inlet temperature45 °C
Air connectionG 1 1/2
Dimensions / L × W × H940 × 530 × 1850 mm
Reference weight285 kg
Catalogue voltage220 V
Catalogue power limit2.5 kW
Application & installation
Drying methodTwin-tower desiccant adsorption with micro-heat regeneration
Selection inputsAir flow / inlet temperature / working pressure / required air quality
Electrical configurationFrequency, phase and final voltage confirmed with quotation
Air treatmentPre-filtration and downstream dust filtration matched to the application
Other configurationsHeatless models available on request

Rated air flow capacity is the compressed-air flow the dryer can treat, not air produced by the dryer. Match the rating basis, inlet and ambient temperatures, working pressure and required pressure dew point to your system. For desiccant dryers, allow for regeneration air when assessing the net flow available to production.

11 m³/min388.5 CFM6–10 barG 21030 × 550 × 1970
SJKW-11 / Full specifications

SELECTED MODEL

SJKW-11

11 m³/min / Micro-heat regenerative desiccant dryer

Equipment specifications
ModelSJKW-11
Drying configurationMicro-heat
Rated air flow capacity11 m³/min / 388.5 CFM
Working pressure6–10 bar
Maximum inlet temperature45 °C
Air connectionG 2
Dimensions / L × W × H1030 × 550 × 1970 mm
Reference weight375 kg
Catalogue voltage220 V
Catalogue power limit2.5 kW
Application & installation
Drying methodTwin-tower desiccant adsorption with micro-heat regeneration
Selection inputsAir flow / inlet temperature / working pressure / required air quality
Electrical configurationFrequency, phase and final voltage confirmed with quotation
Air treatmentPre-filtration and downstream dust filtration matched to the application
Other configurationsHeatless models available on request

Rated air flow capacity is the compressed-air flow the dryer can treat, not air produced by the dryer. Match the rating basis, inlet and ambient temperatures, working pressure and required pressure dew point to your system. For desiccant dryers, allow for regeneration air when assessing the net flow available to production.

14 m³/min494.4 CFM6–10 barG 21160 × 600 × 2010
SJKW-14 / Full specifications

SELECTED MODEL

SJKW-14

14 m³/min / Micro-heat regenerative desiccant dryer

Equipment specifications
ModelSJKW-14
Drying configurationMicro-heat
Rated air flow capacity14 m³/min / 494.4 CFM
Working pressure6–10 bar
Maximum inlet temperature45 °C
Air connectionG 2
Dimensions / L × W × H1160 × 600 × 2010 mm
Reference weight500 kg
Catalogue voltage220 V
Catalogue power limit3.5 kW
Application & installation
Drying methodTwin-tower desiccant adsorption with micro-heat regeneration
Selection inputsAir flow / inlet temperature / working pressure / required air quality
Electrical configurationFrequency, phase and final voltage confirmed with quotation
Air treatmentPre-filtration and downstream dust filtration matched to the application
Other configurationsHeatless models available on request

Rated air flow capacity is the compressed-air flow the dryer can treat, not air produced by the dryer. Match the rating basis, inlet and ambient temperatures, working pressure and required pressure dew point to your system. For desiccant dryers, allow for regeneration air when assessing the net flow available to production.

17 m³/min600.3 CFM6–10 barDN 651200 × 700 × 2080
SJKW-17 / Full specifications

SELECTED MODEL

SJKW-17

17 m³/min / Micro-heat regenerative desiccant dryer

Equipment specifications
ModelSJKW-17
Drying configurationMicro-heat
Rated air flow capacity17 m³/min / 600.3 CFM
Working pressure6–10 bar
Maximum inlet temperature45 °C
Air connectionDN 65
Dimensions / L × W × H1200 × 700 × 2080 mm
Reference weight640 kg
Catalogue voltage220 V
Catalogue power limit3.5 kW
Application & installation
Drying methodTwin-tower desiccant adsorption with micro-heat regeneration
Selection inputsAir flow / inlet temperature / working pressure / required air quality
Electrical configurationFrequency, phase and final voltage confirmed with quotation
Air treatmentPre-filtration and downstream dust filtration matched to the application
Other configurationsHeatless models available on request

Rated air flow capacity is the compressed-air flow the dryer can treat, not air produced by the dryer. Match the rating basis, inlet and ambient temperatures, working pressure and required pressure dew point to your system. For desiccant dryers, allow for regeneration air when assessing the net flow available to production.

22 m³/min776.9 CFM6–10 barDN 651300 × 700 × 2080
SJKW-22 / Full specifications

SELECTED MODEL

SJKW-22

22 m³/min / Micro-heat regenerative desiccant dryer

Equipment specifications
ModelSJKW-22
Drying configurationMicro-heat
Rated air flow capacity22 m³/min / 776.9 CFM
Working pressure6–10 bar
Maximum inlet temperature45 °C
Air connectionDN 65
Dimensions / L × W × H1300 × 700 × 2080 mm
Reference weight700 kg
Catalogue voltage380 V
Catalogue power limit4.5 kW
Application & installation
Drying methodTwin-tower desiccant adsorption with micro-heat regeneration
Selection inputsAir flow / inlet temperature / working pressure / required air quality
Electrical configurationFrequency, phase and final voltage confirmed with quotation
Air treatmentPre-filtration and downstream dust filtration matched to the application
Other configurationsHeatless models available on request

Rated air flow capacity is the compressed-air flow the dryer can treat, not air produced by the dryer. Match the rating basis, inlet and ambient temperatures, working pressure and required pressure dew point to your system. For desiccant dryers, allow for regeneration air when assessing the net flow available to production.

27 m³/min953.5 CFM6–10 barDN 801300 × 700 × 2350
SJKW-27 / Full specifications

SELECTED MODEL

SJKW-27

27 m³/min / Micro-heat regenerative desiccant dryer

Equipment specifications
ModelSJKW-27
Drying configurationMicro-heat
Rated air flow capacity27 m³/min / 953.5 CFM
Working pressure6–10 bar
Maximum inlet temperature45 °C
Air connectionDN 80
Dimensions / L × W × H1300 × 700 × 2350 mm
Reference weight800 kg
Catalogue voltage380 V
Catalogue power limit4.5 kW
Reference pressure dew point-45 °C
Application & installation
Drying methodTwin-tower desiccant adsorption with micro-heat regeneration
Selection inputsAir flow / inlet temperature / working pressure / required air quality
Electrical configurationFrequency, phase and final voltage confirmed with quotation
Air treatmentPre-filtration and downstream dust filtration matched to the application
Other configurationsHeatless models available on request

Rated air flow capacity is the compressed-air flow the dryer can treat, not air produced by the dryer. Match the rating basis, inlet and ambient temperatures, working pressure and required pressure dew point to your system. For desiccant dryers, allow for regeneration air when assessing the net flow available to production.

Listed models use micro-heat regeneration; heatless alternatives are available for discussion. Listed specifications and photographs are references; final conditions and equipment are confirmed with quotation.

SERIES OVERVIEW

Micro-heat regeneration for controlled moisture removal.

SJKW micro-heat regenerative desiccant air dryers use twin adsorption towers to remove water vapour from compressed air. One tower dries the air while the other regenerates using micro-heat. They serve moisture-sensitive pneumatic processes and installations requiring a lower pressure dew point than refrigerated drying.

Nine selected micro-heat models are shown, covering catalogue flow capacities from 1.5 to 27 m³/min. Choose the dryer by the required pressure dew point and the actual inlet conditions. Discuss the regeneration arrangement and its air or electrical requirements as part of the complete system. Heatless alternatives are also available on request.

01 / MATEOU

Start with the moisture specification

Define the pressure dew point required by the application and the lowest temperature the downstream pipework may experience. Confirm the achievable rating for the selected configuration before choosing the equipment.

02 / MATEOU

Protect the drying media

The upstream treatment arrangement should suit the dryer requirements and the condition of the compressed air. Appropriate filtration and condensate control help protect the adsorbent; downstream filtration may be needed to control desiccant dust.

03 / MATEOU

Allow for regeneration duty

Include the regeneration requirement in the air-station review rather than counting only the production airflow. Compare the selected micro-heat configuration with a heatless alternative where operating conditions and maintenance plans make that useful.

Application considerations

Discuss desiccant drying for moisture-sensitive pneumatic processes, instrumentation and installations with a specified low pressure dew point. Air-quality requirements for direct product contact must be evaluated for the complete treatment system.

SELECTION & SUPPORT

Match drying
to your process.

Share your compressor air delivery, working pressure, inlet temperature, installation environment and required air quality. We can review the dryer size, filtration, drainage and electrical supply for your system.

COMMON QUESTIONS

More detail before you decide.

What pressure dew point does this dryer achieve?

The required and achievable pressure dew point must be confirmed for the selected configuration and operating conditions. Send the process specification rather than assuming a single rating for every model.

Is filtration still required with a desiccant dryer?

Yes, the filtration arrangement must match the inlet air condition and the dryer requirements. Discuss protection from oil and liquid water upstream and the need for particle filtration downstream.

Can you supply a heatless alternative?

Heatless desiccant configurations can be discussed on request. Compare the flow capacity, regeneration demand, dew point requirement and electrical supply before deciding.

Chat on WhatsApp

MATEOU / EQUIPMENT FINDER

Let's find your air solution.

Enter what you know. Leave unknown values blank. The displayed screw compressors are oil-injected; sensitive air-quality applications need a separate review.

Working pressure optional

bar · psi · MPa · kPa · kgf/cm² · mbar
Use gauge pressure, measured above atmospheric pressure.

Required compressed air flow optional

m³/min · CFM · L/min · m³/h · L/s · m³/s
Use the equipment air demand on a free-air basis. Do not enter the volume flowing inside a pressurised pipe.

Initial catalogue matches. Final selection also depends on duty cycle, air quality, power supply and installation conditions.